Fuel flow meter
DPT 5.2 / DPT 7.2


Function
Fuel flow meter DPT is designed for measuring diesel fuel consumption in the fuel line of vehicles and installations.

Applications
Fuel flow meter DPT is to be used together with fuel monitoring (FMS), AVL, GPS Tracking systems installed on the following vehicles: 
  • Trucks
  • Tractive vehicles
  • Tractors of various types
  • Loaders
  • Graders
  • Road-building machinery
  • Technological transport
  • Fixed installations with diesel engines and so on

It is possible to use fuel flow meter DPT on the river and rail diesel transport.


Mounting 
Fuel flow meter DPT is mounted into the fuel line of vehicles according to the approved installation schemes of DPT 5.2 / DPT 7.2. Fuel pipe and Installation kit cab be additionally included in the delivery set. Installation kit includes: angle pieces, calibrated bypass valve, check valve, connection clips, screws and so on.

Compatibility
Fuel flow meter DPT can operate as a part of on-board terminals which have discrete or pulse input 0-32V, for example with Off-line fuel monitor CKPT 31 Lite, on-line terminal CKPT 45, Teltonica, etc.

Principle of operation  
Fuel flow meter DPT transforms fuel flow volume into a number of impulses (5 ml for DPT 5.2 and 7,5 ml for DPT 7.2).

Advantages
  • Light-emitting diode indication of the sensor work;
  • Minimum resistance to the fuel flow;
  • High wear proofness;
  • Built-in filter;
  • Seal for prevention of unauthorized sensor opening;
  • 100% control on the metrological certified installation. 
     fuel flow meter DPT 5.2, DPT 7.2
Specification
Flow rate DPT-5.2 - 2..80 l/h
DPT-7.2 - 5..200 l/h
 
Measurement accuracy

 ±1%

 
Supply voltage 10-50 V  
Protection up to 100 V  
Operating temperature from -40 to +85 оС  
Operating pressure up to 25 atm  
Current consumption
< 10 mA  
Protection class 
IP 54  
Output signal pulse  
Operating fluids diesel fuel, heating fuel, engine oil and other fluids with kinematic viscosity from 1,5 to 6 mm2/sec  
Weight 1 kg  
Overall dimensions 110x120x86 mm  

 Warranty
  • Warranty period is 24 months from the vintage
  • Mean time between failures (MTBF) is no less than 5 000 hours
  • Mean lifetime is no less than 5 years

 


 

 see also Fuel level sensor DUT-E, Fuel flow sensor DPT 5 OEM